FC200 Operating Specifications
- Operating fluid pressure range: 0 to 172 kPa ( 0 to 15 psig) @ 80°C (176°F)
- Operating fluid temperature range: 1 to 80°C (33 to 176°F)
- Maximum Pressure differential on tubing: 35 kPa (0 to 5 psid) @ 80°C (176°F)
- Negative pressure differential will collapse tubing and must be avoided
- Storage temperature range: -30 to 60°C (-22 to 140°F)
FC200 Materials of construction
- Housing / Shell – Polypropylene
- End caps – GE Noryl
- Seals – EPDM (peroxide cured)
- Tube bundle headers – Thermoset polyurethane
- Membrane tubing – Nafion™ polymer
IMPORTANT – WARNING! Due to differing rates of expansion, metal fittings are not recommended. ABS or Nylon fittings are recommended. Additionally, DO NOT USE a thread sealant compound when attaching fittings to Perma Pure humidifiers, it is chemically incompatible with the assembly, leading to leaks (and voiding the warranty). Use Teflon tape instead.