Baldwin Model 45 Dilution Probes

Baldwin™ -Series Model 45 Dilution Probe conditioning systems from Perma Pure draw, filter and dilute sample gases in preparation for analysis. The out-of-stack conditioning system dilutes the sample gas 10 to 250 times with dry air, reducing the water vapor content and eliminating high-cost heated lines. Features Include:

  • Selectable dilution ratios
  • Out-of-stack orifice
  • Dilution air pre-heater
  • Optional fast loop bypass
  • Plug-free operation
  • Corrosion resistant Fiberglass enclosure
  • Self-regulating temperature
  • Wet basis measurement
  • Sure-Lock™ stack mounted filter holder assembly w/ air ballast tank
  • Heater band with type K thermocouple, requires external control
  • Single direct blowback; 2-way solenoid blowback valve
  • Integral calibration gas port; eductor w/air pre-heater, check valve 0.3 psig
  • 1-1/4 male pipe nipple mount,1/2″ female pipe thread for stinger

Principle of Operation

A precision, low flow, heated dilution eductor assembly driven by instrument quality air extracts sample gas from the process. The sample passes through a stinger and filter probe to remove particulate. The filter element is selected for its inertness to the sample gas; a ceramic element is standard. A conditioned source of instrument air connects to the dilution eductor. The flow through the critical orifice in the eductor creates the vacuum that pulls the sample gas through the dilution probe system. This air mixes with the sample, diluting the gas to a lower concentration and dew point. The dilution air and sample gas flow rate may be set by selecting a different orifice size. This orifice is made from precisely machined Monel. The design of the orifice restricts the gas flow to achieve sonic levels or the speed of sound, eliminating the effects of pressure fluctuations downstream. To maintain a constant dilution ratio, the precision dilution eductor draws the sample in at a slow rate of 25-700 cc/min. An optional fast loop eductor is available to reduce lag time between the probe tip and filter body, ensuring adequate sample supply.

Specifications

Model Number 4P-45
Enclosure NEMA 4X fiberglass with 3/8″ Rubatex/silicone insulation
Dimensions 19″ x 17″ x 10″ HWD
Weight 25 lbs. w/o stinger & flanges
Electrical Requirements – Probe 90-260 VAC, 50/60 Hz, 600 Watts
Electrical Requirements – Blowback Solenoid 120 VAC standard, 230 VAC (optional 24 VDC)
Max. sample gas
inlet temperature
45°F / 230°C with silicone rubber O- rings;
600°F / 318°C with Kalrez™ o-rings
Filter Element 2 micron, 3″ ceramic, 90 cc internal volume, standard
(optional Teflon™, SS, SS mesh 0.1-20μm)
Filter Housing 316L stainless steel, 160 cc internal volume
(optional Durinert™ or Teflon coating)

45 Series Dilution Probe Intelligent Product Numbering System

part-numbers-baldwin-45-Series

1 – Voltage
115 VAC, 50/60 Hz 1A
230 VAC, 50 Hz 2A
2 – Filter Element, 3″ (Required Option)
2 micron ceramic, standard C2
0.1 micron glass C1
0.7 micron glass / TFE coated C7
2 micron Teflon T2
3 – Coatings
Durinert -PLUS coating, probe body and stinger DS
Durinert -PLUS coating, probe body only DP
Teflon coated filter head TC
4 – Fast loop
Eductor to reduce probe response time 1
5 – Flange
2″, 150# with gasket & bolts 2
Gas cooling spool piece: w/2″ flanges & 6″ spool 2A
Gas cooling spool piece: w/2″ flanges & 12″ spool 2B
3″, 150# with gasket & bolts 3
Gas cooling spool piece: w/3″ flanges & 6″ spool 3A
Gas cooling spool piece: w/3″ flanges & 12″ spool 3B
4″, 150# with gasket & bolts 4
Gas cooling spool piece: w/4″ flanges & 6″ spool 4A
Gas cooling spool piece: w/4″ flanges & 12″ spool 4B
6″, 150# with gasket & bolts 6
6 – Dilution Ratio (required Option)
100:1 1
20:1 2
40:1 4
7 – Stinger
18″, 316L stainless steel, 1/2″, schedule 40 41
2-foot, 316L stainless steel, 1/2″, schedule 40 42
3-foot, 316L stainless steel, 1/2″, schedule 40 43
4-foot, 316L stainless steel, 1/2″, schedule 40 44
5-foot, 316L stainless steel, 1/2″, schedule 40 45
18″, 316L stainless steel, 1/2″, schedule 80 81
2-foot, 316L stainless steel, 1/2″, schedule 80 82
3-foot, 316L stainless steel, 1/2″, schedule 80 83
4-foot, 316L stainless steel, 1/2″, schedule 80 84
5-foot, 316L stainless steel, 1/2″, schedule 80 85
18″, Hastelloy C276, 1/2″, schedule 80 H1
2-foot, Hastelloy C276, 1/2″, schedule 80 H2
3-foot, Hastelloy C276, 1/2″, schedule 80 H3
4-foot, Hastelloy C276, 1/2″, schedule 80 H4
5-foot, Hastelloy C276, 1/2″, schedule 80 H5
8 – Blowback Solenoid Voltage; line voltage standard
2-Way solenoid, 12 VDC 12
2-Way solenoid, 24 VDC 24

Baldwin 45 Series Dilution Probe Spare Parts

ITEM # Description
1TTC-012 Thermocouple, additional type K, 12″ lug-style lead wire for readout only
3FES-015PK Filter element seals: silicone, used w/ screen mesh 3FES-010 (10 pack)
3FES-010 Filter element: 316L SS screen mesh, 2.0 micron
3FES-002 Filter element: 316L SS, 1.25” x 2.975”, 2 micron
3FES-004 Filter element: 316L SS, 1.25” x 2.975”, 10 micron
3FES-003 Filter element: 316L SS, 1.25” x 2.975”, 20 micron
3FES-005 Filter element: 316L SS, 1.25” x 2.975”, 5 micron
3FEC-002 Filter element: Ceramic 2 micron
3FEG-001 Filter element: Glass, 0.1 micron
3FET-002 Filter element: 2 micron Teflon
3FEG-003 Filter element: Glass/TFE Coated, 0.7 micron