Notes on Baldwin eCool Series Thermoelectric Gas Sample Coolers
Baldwin’s general purpose versions of the e-Cool line has been replaced by the new Digital Cooler Line. The only eCool models currently available have CSA Class 1, Division 2 approvals. Please Contact Us for technical support or spare parts availability.
A revolution in gas sample conditioning, the Baldwin-Series eCool™ coolers offer all the water removal features of the “Classic” series with the additional convenience of digital controls for remote monitoring and data collection.

  • Remote control and monitoring of probe, sample line and cooler
  • Digital control via custom windows application over a network or Modbus over TCP/IP
  • CSA Rated Class I, Division II – e5500XP, e5800XP, e5900XP
  • CE Marked

Baldwin eCool Series Product Selection Guide

Baldwin-ecool-selection

Cooler Flow Rate Hazardous Area
4-7 lpm (8-15 scfh); 440 Btu/hr Baldwin e5500XP eCool Series
7-10 lpm (15-21 scfh); 124 Btu/Hr Baldwin e5800XP eCool Series
10-20 lpm (21.2-42.4scfh); 1200 Btu/Hr Baldwin e5900XP eCool Series